2011.01.31 1
INDOOR UNIT H x W x D
H x W x D
320 x 998 x 228 mm
OUTDOOR UNIT 830 x 900 x 330 mm
DIMENSIONS
INDOOR UNIT Shipping / Net
Shipping / Net
18 kg / 14 kg
OUTDOOR UNIT 68 kg / 61 kg
WEIGHT
SPECIFICATIONS
TYPE Cool & heat inverter
INDOOR UNIT
OUTDOOR UNIT
ASYA30LFC
AOYR30LFT
COOLING CAPACITY
HEATING CAPACITY
POWER SOURCE 230 V
FREQUENCY 50 Hz
RUNNING
CURRENT
MAXIMUM
CURRENT
COOLING
HEATING
INPUT WATTS COOLING
HEATING
E.E.R. COOLING
COP HEATING
MOISTURE REMOVAL
AIR CIRCULATION HIGH 1,100 m3/hr
8.00 kW
8.80 kW
10.9 A
10.7 A
COOLING
HEATING
17.0 A
19.0 A
2.49 kW
2.44 kW
3.21 kW/kW
3.61 kW/kW
3.2 L/hr
FAN MOTOR
TYPE
Hermetic type,
4 pole, Rotary,
DC inverter motor
DISCRIMINATION
WEIGHT WITH OIL
N-TF30ND1A
REFRIGERANT TYPE
PRECHARGED REFRIGERANT
R410A
2,100 g
15.5 kg
POWER SOURCE 230 V
High 1,430 r.p.m.
INDOOR UNIT
(Cool)
Medium 1,220 r.p.m.
Low 1,020 r.p.m.
Quiet
OUTDOOR UNIT (Cool)
OUTDOOR UNIT (Heat)
900 r.p.m.
High 1,530 r.p.m.
INDOOR UNIT
(Heat)
Medium 1,220 r.p.m.
Low 1,020 r.p.m.
Quiet 900 r.p.m.
850 r.p.m.
850 r.p.m.
ELECTRICAL DATA
COMPRESSOR AND REFRIGERANT
NOISE LEVEL
Pipe length 20 m 2,100 g
FULL CHARGE 50 m 3,300 g
ADDITIONAL CHARGE 40 g/m
MAXIMUM HEIGHT 30 m
High 49 dB
INDOOR UNIT
(Heat)
Medium 42 dB
Low 37 dB
Quiet 33 dB
High 48 dB
INDOOR UNIT
(Cool)
Medium 42 dB
Low 37 dB
Quiet 33 dB
OUTDOOR UNIT (Cool)
OUTDOOR UNIT (Heat) 55 dB
53 dB