- (02 - 06) -
OUTDOOR UNIT
AOÝG09-12LLC
OUTDOOR UNIT
AOÝG09-12LLC
CAPACITY COMPENSATION RATE FOR PIPE LENGTH 5.
AND HEIGHT DIFFERENCE
MODEL
¢ : AOÝG09LLC
Height difference H
Ý1 Indoor unit is higher than outdoor unit. Ý2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
57.5 10 15
Height difference H
(m)
Û1
Indoor unit is higher
than outdoor unit.
10 - - 0.944 0.897
7.5 - 0.983 0.944 0.897
5 1.000 0.983 0.944 0.897
0 1.000 0.983 0.944 0.897
Û2
Indoor unit is lower
than outdoor unit
-5 0.995 0.978 0.939 0.892
-7.5 -0.976 0.937 0.891
-10 - - 0.935 0.889
COOLING
Pipe length (m)
57.5 10 15
Height difference H
(m)
Û1
Indoor unit is higher
than outdoor unit.
10 - - 0.980 0.944
7.5 - 0.988 0.984 0.948
5 0.992 0.992 0.988 0.951
0 1.000 1.000 0.995 0.960
Û2
Indoor unit is lower
than outdoor unit
-5 1.000 1.000 0.995 0.960
-7.5 - 1.000 0.995 0.960
-10 - - 0.995 0.960