- (01 - 20) -
WALL MOUNTED TYPE
ASÝG09-12LLCA
WALL MOUNTED TYPE
ASÝG09-12LLCA
4) Auto restart
Enable or disable automatic system restart after a power outage.
(¿
... Factory setting)
Setting description Function number Setting value
¿Yes 40 00
No 01
* Auto restart is an emergency function such as for power failure etc.
Do not start and stop the indoor unit by this function in normal operation.
Be sure to operate by the control unit, or external input device.
5) Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
(¿
... Factory setting)
Setting description Function number Setting value
¿A
44
00
B01
C 02
D 03
6) Indoor unit fan control for energy saving(Only cooling mode)
Enable or disable indoor unit fan control when the outdoor unit is stopped.
(¿
... Factory setting)
Setting description Function number Setting value
No 49 00
¿Yes 01
* If setting value is "00":
When the outdoor unit is stopped, the indoor unit fan operates following the setting on the
remote controller continuously.
* If setting value is "01":
When the outdoor unit is stopped, the indoor unit fan operates at very low speed intermittently.
Terms of Use | Privacy Policy | DMCA Policy