- (01 - 19) -
WALL MOUNTED TYPE
ASÝG09-12LLCA
WALL MOUNTED TYPE
ASÝG09-12LLCA
FUNCTION DETAILS
¢
Functions Wall mounted
1) Filter sign
2) Cooler room temperature correction
3) Heater room temperature correction
4) Auto restart
5) Remote controller signal code
6) Indoor unit fun control for energy saving
1) Filter sign
The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time
setting for the filter sign display interval in the table below according to the amount of dust or
debris in the room. If you do not wish the filter sign to be displayed, select the setting value for
"No indication".
(¿
... Factory setting)
Setting description Function number Setting value
Standard
11
00
Long interval 01
Short interval 02
¿No indication 03
The filter sign interval time is different according to Indoor unit type as follows.
Setting description Wall mounted
Standard 400 hours
Long interval 1000 hours
Short interval 200 hours
2) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be selected as shown in the table below.
(¿
... Factory setting)
Setting description Function number Setting value
¿Standard
30
00
Slightly lower control 01
Lower control 02
Warmer control 03
3) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be changed as shown in the table below.
(¿
... Factory setting)
Setting description Function number Setting value
¿Standard
31
00
Lower control 01
Slightly warmer control 02
Warmer control 03