DRAIN PAN VALVE
TESTING THE HEATING ELEMENTS AND
LIMIT SWITCHES
HEATER ELEMENTS AND LIMIT SWITCHES’
SPECIFICATIONS
-
-
-
230 VOLTS HEATERS
2.5 KW, 230 V, 18.61 Ohms + - 5%.
135° F,
Closes at 130° F.
200° F.
3.4 KW, 230 V, 13.68 Ohms + - 5%.
135° F,
Closes at 130° F.
200° F.
5 KW, 230 V, 9.31 Ohms + - 5%.
145° F,
Closes at 130° F.
200° F.
265 VOLTS HEATERS
2.5 KW, 265 V, 24.71 Ohms + - 5%.
135° F,
Closes at 130° F.
200° F.
3.4 KW, 265 V, 18.17 Ohms + - 5%.
145° F,
Closes at 130° F.
200° F.
5 KW, 265 V, 12.35 Ohms + - 5%.
145° F,
Closes at 130° F.
200° F.
NOTE: Always replace with an exact replacement.
COMPONENTS TESTING (Continued)
ELECTRIC SHOCK HAZARD
WARNING