6
SPECIFICATIONS (CONTINUED)
UNIT SIZE 080 --- 16 080 --- 20 100 --- 16 100--- 20 120--- 20 140 --- 20
RATINGS AND PERFORMANCE
Input Btuh* 80,000 80,000 100,000 100,000 120,000 138,000
Output Capacity
BTUH* (ICS)
(Shaded capa-
cities are spe-
cified on rating
p
late
)
D i r e c t V e n t ( 2 --- P i p e )
Upflow 75,000 75,000 94,000 94,000 113,000 129,000
Downflow 75,000 75,000 94,000 94,000 113,000 129,000
Horizontal 75,000 75,000 93,000 93,000 112,000 128,000
N o n --- D i r e c t V e n t ( 1 --- P i p e )
Upflow 75,000 75,000 94,000 94,000 112,000 NA
Downflow 75,000 75,000 93,000 93,000 113,000 NA
Horizontal 75,000 75,000 93,000 93,000 112,000 NA
AFUE%
Nonweatherized
ICS
D i r e c t V e n t ( 2 --- P i p e )
Upflow 93.0 92.6
Downflow 91.5 91.2
Horizontal 92.3 92
N o n --- D i r e c t V e n t ( 1 --- P i p e )
Upflow 92.4 NA
Downflow 91.4 NA
Horizontal 91.4 NA
Certified Temperature Rise Range ° F (° C) 30---60
( 1 7 --- 3 3 )
20---50
( 1 1 --- 2 8 )
45---75
( 2 5 --- 4 1 )
30---60
( 1 7 --- 3 3 )
40---70
( 2 2 --- 3 9 )
50---80
( 2 8 --- 4 4 )
Certified External Static Pressure Heating 0.15 0.15 0.20 0.20 0.20 0.20
Cooling 0.50 0.50 0.50 0.50 0.50 0.50
Airflow CFM}Heating 1285 1785 1315 1690 1720 1970
Cooling 1525 1925 1570 1930 2000 1990
ELECTRICAL
U n i t V o l t s --- H e r t z --- P h a s e 1 1 5 --- 6 0 --- 1
Operating Voltage Range Min ---Max** 104---127
Maximum Unit Amps 10.1 14.1 10.2 14.8 14.6 14.6
Unit Ampacity{{ 13.4 18.4 13.5 19.3 19.1 18.8
Minimum Wire Size 14 12 14 12 12 12
M a x i m u m W i r e L e n g t h --- F t ( M ) }} 28
(8.5)
31
(9.4)
27
(8.2)
30
(9.1)
30
(9.1)
30
(9.1)
Maximum Fuse Size or Ckt Bkr Amps (Time---Delay Type Recommended) 15 20 15 20 20 20
Transformer (24v) 40va
External Control Power Available Heating 12va
Cooling 21va
Air Conditioning Blower Relay Standard
CONTROLS
Limit Control SPST
Heating Blower Control (Off Delay) Selectable 90, 120, 150, or 180 Sec
Burners (Monoport) 445566
Gas Connection Size 1 / 2 --- i n . N P T
GAS CONTROLS
Gas Valve (Redundant)
Manufacturer W h i t e --- R o d g e r s
Min Inlet Pressure (In. wc) 4.5 (Natural Gas)
Max Inlet Pressure (In. wc) 13.6 (Natural Gas)
Ignition Device Hot Surface
BLOWER DATA
Direct---Drive Motor HP (Permanent Split Capacitor) 1/2 3/4 1/2 3/4 3/4 3/4
Motor Full Load Amps 7.9 11.1 7.9 11.1 11.1 11.1
R P M ( N o m i n a l ) --- S p e e d s 1075---4
Blower Wheel Diameter x Width --- In. (mm)
11 x 8
(279 x
203)
11 x 10
(279 x
254)
11 x 8
(279 x
203)
11 x 10
(279 x
254)
11 x 10
(279 x
254)
11 x 10
(279 x
254)
F i l t e r S i z e --- I n . ( m m )
(1)16 x
25 x 3/4
(406 x
635 x
19)
(1) 20 x 25 x 3/4
(508 x 635 x 19)
(1)24 x 25 x 3/4
(610 x 635 x 19)
FACTORY--- AUTHORIZED AND LISTED, DEALER--- INSTALLED OPTIONS
G a s C o n v e r s io n K i t --- N a t u r a l --- t o --- P r o p a n e KGANP4601ALL
G a s C o n v e r s io n K i t --- P r o p a n e --- t o --- N a t u r a l KGAPN3901ALL
Twinning Kit KGATW0601HSI N/A
Manufactured (Mobile) Home Kit KGAMH0301KIT N/A
Downflow Base*** KGASB0301ALL
Vent Termination Kit (Bracket Only for 2 Pipes) 2---in. ---KGAVT0101BRA 3---in. ---KGAVT0201BRA
Concentric Vent Termination Kit (Single Exit) 2---in. ---KGAVT0701CVT 3 ---in.---KGAVT0801CVT
Condensate Freeze Protection Kit KGAHT0101CFP
Condensate Neutralizer Kit (Obtained Thru RCD) P908---0001
Side Filter Rack (Without Filter)---Upflow ONLY KGAFR0206ALL
Electronic/Mechanical Air Cleaner Model EACB, EZXCAB, or FILCAB
Humidifier Model HUM
Heat/EnergyRecoveryVentilator Model HRV
UV Lights Model UVL
Door Gasket Kit KGBAC0110DGK
Unframed Filter Permanent Washable 3/4---in. (19 mm) thick
16 x 25 (406 x 635)
24 x 25 (610 x 635)
KGAWF1306UFR
KGAWF1506UFR
* Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 2% for each 1000 ft. (305 M) above sea
level. In Canada, derate the unit 5% from 2000 to 4500 ft. (610 to 1372 M) above sea level.
{Capacity and AFUE in accordance with U.S. Government DOE test procedures.
}Airflow shown is for bottom only return---air supply. Air delivery above 1800 CFM may require that both sides, a combination of 1 side and bottom, or bottom
only of the furnace be used for return air, see Air Delivery table. Where 2 sets of data are listed, the first set is for bottom only return---air supply. The second set
isforbothsides,or1sideandbottomreturn---airsupply.Afilterisrequiredforeachreturn---airsupply.
** Permissible voltage limits for proper furnace operation.
{{ Unit ampacity = 125% of largest component’s full load amps plus 100% of all other potential operating components (EAC, humidifier, etc.).
}} Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
*** Required for installation on combustible floors when no coil box is used, or when any coil box other than a Carrier CD5, CK5, CAP(R), CNP(R), or KCAKC
cased coil is used.
N/A --- Not applicable
ICS --- Isolated Combustion System
58MXB