WFM700/WFM7HD Input Module Test Record
2-68 WFM700 Series Waveform Monitors Service Manual
Test Record (cont.)
Instrument Serial Number: Certificate Number:
Input Module Serial Number:
Temperature: Relative Humidity %:
Date of Calibration: Technician:
Performance Test MaximumOutgoingIncomingMinimum
Error Detection Data Paths
1080i 59.94 0% flat field
Embedded CRC status reads:
Embedded CRC: SMPTE 292 Y:OK C:OK
Pass N/A
1080i 59.94 0% flat field
Gamut errors read as follows:
RGB Gamut Error X OK
Composite Gamut Error X OK
Pass N/A
1080i 59.94 SMPTE color bars
Gamut errors read as follows:
RGB Gamut Error X Alarm
Composite Gamut Error X OK
Pass N/A
1080i 59.94 100% color bars
Gamut errors read as follows:
RGB Gamut Error X OK
Composite Gamut Error X Alarm
Pass N/A
Serial Video Output
Calculated error -- 5 % +5%
SD PIX MON Output Level
Calculated error -- 5 % +5%
PIX Video Output Level
High Definition
PIX G/Y calculated amplitude error -- 5 % +5%
PIX G/Y black level -- 2 5 m V +25 mV
PIX B/Pb calculated amplitude error -- 5 % +5%
PIX B/Pb black level -- 2 5 m V +25 mV
PIX R/Pr calculated amplitude error -- 5 % +5%
PIX R/Pr black level -- 2 5 m V +25 mV