4) DETERMINE DEVICE LENGTH.
A) LOCATE VERTICAL C ON DOOR.
B) MEASURE DISTANCE "Y" FROM VERT. TO STOP SURFACE ON HINGE SIDE.
C) SUBTRACT 1" FOR RECOMMENDED CLEARANCE (FOR DOOR STILES LESS THAN 2-3/4" WIDE, SUBTRACT 3/4").
D) LENGTH OF DEVICE FROM VERT. TO CUT-OFF LENGTH IS "X".
LC
C
L
L
NO
TE: FOR STANDARD DOGGING: 3" MIN.
FOR CYLINDER DOGGING: 4-1/2" MIN.
FOR EXIT ALARM AND ELECTRIC DOGGING: 7" MIN.
LHR SHOWN
5) IF DEVICE IS LONGER THAN "X", CUT THE DEVICE
.
A) MARK DEVICE CHANNEL AND COVER TO LENGTH "X".
B) CUT BOTH CHANNEL AND CHANNEL COVER TO MARKED DIMENSION AND REMOVE BURRS.
NOTE:FACTORY RECOMMENDS SAWING RATHER
THAN GRIND CUT TO SIZE. GRINDING CAN
DAMAGE THE FINISH OF THE DEVICE AND
SAWING RESULTS IN LESS DAMAGE TO THE
DEVICES'S FINISH.
C
L
SEE
NOTE
BELOW
“X” CUT-OFF LENGTH
“Y”
VERT C
L
DEVICE REF. C
L
5/16"
5/16" DIA. HOLE
6) DRILL MOUNTING HOLE
.
REMOVE CHANNEL COVER AND DRILL 5/16" DIA. HOLE ON DEVICE REF. 5/16" FROM END OF CHANNEL.
NOTE:BE SURE CHANNEL COVER IS
PUSHED SNUG TO PUSHBAR PRIOR
TO MARKING OR CUTTING TO SIZE
“X”
SEE ABOVE
LHR SHOWN
3” MINIMUM
(4-1/2” FOR CYLINDER DOGGING
& EXIT ALARM)
10) APPLY STRIKES & COVERS (NOTE: ALL SCREWS ARE BLACK).
A) ATTACH COVERS TO CHASSIS AND LATCHES .
B) INSTALL ROD GUIDES.
C) SLIDE IN CHANNEL COVER.
D) ATTACH CHANNEL END CAP.
E) INSTALL STRIKES TO TOP OF DOOR FRAME AND TO FLOOR OR THRESHOLD.
F) CHECK FOR SMOOTH OPERATION.
B) REMOVE DOGGING KEY; TOUCHBAR WILL REMAIN DEPRESSED.
C) REINSERT DOGGING KEY AND TURN IT IN OPPOSITE DIRECTION (COUNTER-CLOCKWISE).
PUSH ON TOUCHBAR AND IT WILL "POP OUT."
D) FOR CYLINDER DOGGING, REFER TO INSTALLATION INSTRUCTION D-4080.
LHR SHOWN
11)
CHECK DOGGING OPERATION: (PANIC APPLICATION ONLY)
A) DEPRESS TOUCHBAR, INSERT AND TURN DOGGING KEY CLOCKWISE TO DOG DEVICE.
FOR DEVICES ON DOORS OVER 8'0"
TALL, TWO ROD GUIDES SHOULD BE
PLACED EQUALLY BETWEEN THE TOP
LATCH AND DEVICE HEAD.
#10-24x3/8"
UFPHMS (2 QTY.)
#8-32x5/16"
UFPHMS (2 QTY.)
Terms of Use | Privacy Policy | DMCA Policy
2006-2023 Ready to Serve Manuals