Loading...
12
Ordercode: 50825
TR-512
4.3. Show
In this menu you can assign your recorded shows to the desired triggers.
01) Once you have entered the menu, press the UP/DOWN buttons to select the desired show.
02) Press the ENTER button to confirm your choice.
4.4. Mode
In this menu you can set the trigger mode.
01) Once you have entered the menu, press the UP/DOWN buttons to select one of the 4 modes:
NO_TR: Normally Open (Trigger will be activated when the circuit closes. As long as the circuit
remains closed, the triggered show will play in a loop. When the circuit opens, the show will keep
playing until it ends and then it will stop. With only a short pulse, the show will play just once.)
NC_TR: Normally Closed (Trigger will be activated when the circuit opens. As long as the circuit
remains open, the triggered show will play in a loop. When the circuit closes, the show will keep
playing until it ends and then it will stop. With only a short pulse, the show will play just once.)
TOGGLE_TR: It works with NO and NC circuits (external buttons). The first pulse starts the triggered
show to play in a loop. After the second pulse, the show will stop. Another pulse will restart the
show.
AUTO_TR: When set to this mode, the trigger will be activated immediately. Upon every start-up,
the device will always search for any triggers set to this mode and will activate them.
02) Press the ENTER button to confirm your choice.
03) It is possible to use each of the 4 modes at the same time, independently, for separate triggers (1-6).
4.5. Delay
In this menu you can set the delay time.
01) Once you have entered the menu, press the UP/DOWN buttons to set the delay time. The adjustment
range is between 0-120 seconds.
02) Press the ENTER button to save changes.
Note: Once you have adjusted all the options 4.1-4.5, press the UP/DOWN buttons to select CONFIRM &
SAVE (to save a new trigger event) or CANCEL & RETURN (to discard changes and return to the previous
menu). Press the ENTER button to confirm your choice.
5. Stop TR Event
In this menu you can deactivate the desired trigger events.
01) The display will show:
02) Press the UP/DOWN buttons to select the desired trigger event.
03) Press the ENTER button to deactivate the selected trigger event.
04) Repeat steps 2-3 to deactivate the remaining trigger events.