26
APPLICATIONS AND PROTOCOLS
The model number on each scanner includes the scanner number and factory
default communications protocol.
Scanner Version Identifier Communication Protocol(s)
00 Laser Emulation and RS-232 Transmit/Receive
9 OCIA and RS-232 Transmit/Receive
11 IBM 468X/469X, RS232-TXD, RXD, RTS, CTS
14 RS232 - TXD, RXD, RTS, CTS, DTR, DSR
38 Low Speed POS USB
39 Low Speed HID USB
40 Full Speed Integrated USB
41 RS-232/Light Pen Emulation
MS9520
MS9540
47 Keyboard Wedge, Stand-Alone Keyboard and
RS-232 Transmit/Receive
The MS9520/9540 Keyboard Wedge Series (-47) is designed for keyboard
emulation only. Many RS-232 programmable functions available in other
Metrologic scanners are also available as keyboard wedge functions.
The following are the most important selectable options specific to
keyboard wedge:
Keyboard Type
**AT (includes IBM® PS2 models 50, 55, 60, 80)
XT
IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type
**USA German Spanish
Belgium Italian Swiss
French Japanese United Kingdom
** Indicates a default setting (see pages 34-38 for additional information). Refer
to the MetroSelect Single-Line Programming Guide (MLPN 00-02544) or
MetroSet2’s help files for information on how to change the default settings.