70
SCALE OPERATION
CALIBRATION
The scanner/scale must be calibrated if:
it is a first time installation
the scale cannot be re-zeroed
the calibration verification tests indicate errors
there is a change in the units of measure
[i.e. from pounds (lbs.) to kilograms (kg)]
if the scale load cell has been replaced
the calibration seal is missing or torn
The certification of the weighing mechanism of the scale version of this
scanner is subject to federal, state and local Weights and Measures
statutes and regulations and can only be performed by authorized
government agencies and/or their duly registered agents. Each time the
scale or weighing mechanism is calibrated, it should be properly sealed
with a paper seal or a wire seal prior to being placed into service in
commerce.
It is the responsibility of the owner of the scale to confirm compliance
with the relevant Weights and Measures statutes and regulations
applicable in your area by checking with the appropriate government
agency before placing a newly calibrated unit into service or removing
any official seals.
Tools Required
Field Standard 30.0 pound Weight Set or 15.0 kilogram Weight Set
Wire or Paper Seal
Type of seal to be used will depend on the guidelines specified
by the local Weights and Measures authorities.
Phillips #1 Screw Driver
Scale Calibration Methods
Scale Calibration with Remote Display uses the scale display to
sequence through the calibration steps and store critical calibration
points.
Bar Code Scale Calibration without Remote Display* uses the
scanner / scale only and assumes there is no remote scale display.
A bar code is used to initiate the calibration sequence and the speaker
volume switch is used to store critical range values.
* This calibration procedure will work with the remote display connected to the
Stratos but no data will appear on the remote display.