101
DEFAULT SETTINGS
COMMUNICATION PARAMETERS
PARAMETER DEFAULT OCIA RS232 IBM
46XX USB
Bookland 9 9 9 9
Convert Bookland to ISBN 9 9 9 9
Reformat ISBN 9 9 9 9
Transmit ISBN Check Digit 9 9 9 9
Bookland 977 2-Digit Supp Required 9 9 9 9
378 / 379 Supplements 9 9 9 9
414 / 419 Supplements 9 9 9 9
434 / 439 Supplements 9 9 9 9
Number System 2 Enables
Supplements 9 9 9 9
Number System 5 Enables
Supplements 9 9 9 9
100 msec to Find Supplement
(100 - 800 msec) *9 9 9 9
Allow Code ID’s with Supplements 9 9 9 9
High Density Codes *9 9 9 9
Medium Density Codes 9 9 9 9
Low Density Codes 9 9 9 9