Loading...
MOTOROLA M68040 USER’S MANUAL A- 9
A.6.4 Power Dissipation
Frequency Watts
Maximum Values (VCC = 5.25 V, TA = 0°C)
20 MHz 3.2
25 MHz 3.9
33 MHz 4.9
Typical Values (VCC = 5 V, TA = 25°C)*
20 MHz 2.0
25 MHz 2.4
33 MHz 3.0
*This information is for system reliability purposes.
A.6.5 Clock AC Timing Specifications (see Figure A-4)
20 MHz 25 MHz 33 MHz
Num Characteristic Min Max Min Max Min Max Unit
Frequency of Operation 16.67 20 16.67 25 16.67 33 MHz
1 PCLK Cycle Time 25 30 20 30 15 30 ns
2 PCLK Rise Time 1.7 1.7 1.7 ns
3 PCLK Fall Time 1.6 1.6 1.6 ns
4 PCLK Duty Cycle Measured at 1.5 V 48 52 47.5 52.5 46.67 53.33 %
4a* PCLK Pulse Width High Measured at 1.5 V 12 13 9.5 10.5 7 8 ns
4b* PCLK Pulse Width Low Measured at 1.5 V 12 13 9.5 10.5 7 8 ns
5 BCLK Cycle Time 50 60 40 60 30 60 ns
6,7 BCLK Rise and Fall Time —4—4—3ns
8 BCLK Duty Cycle Measured at 1.5 V 40 60 40 60 40 60 %
8a* BCLK Pulse Width High Measured at 1.5 V 20 30 16 24 12 18 ns
8b* BCLK Pulse Width Low Measured at 1.5 V 20 30 16 24 12 18 ns
9 PCLK, BCLK Frequency Stability 1000 1000 1000 ppm
10 PCLK to BCLK Skew —9—9—n/ans
*Specification value at maximum frequency of operation.