4 - 18 DS9208 Product Reference Guide
Post Decode Illumination
Parameter # F2h 29h
This parameter controls illumination after decode. Select Always Off to turn off illumination immediately after
decode. Select Always On to keep Illumination on after decode so the scanner is ready for next decode, or to keep
illumination on until timeout.
Presentation Mode Field of View
Parameter # F1h 61h
In presentation mode, by default the digital scanner searches the larger area of the aiming pattern (Full Field of
View).
To search for a bar code in a smaller region around the aiming pattern’s center cross in order to speed search time,
select Small Field of View or Medium Field of View.
Always On
(00h)
*Always Off
(01h)
Small Field of View
(00h)
Medium Field of View
(01h)
*Full Field of View
(02h)