Loading...
Operations
Control Panel LCD Display
60
13291L-001 Rev. A S4M Maintenance Manual 10/27/05
MODULE B
(APL-D mode only)
Set Module B Storage Device for APL-D
Selections: NONE, RAM 1, RAM 2, FLASH 1, FLASH 2
Default Value: NONE
To modify this parameter:
Press the up or down arrow to scroll through the selections.
PARALLEL COMM. Set Parallel Communications
Select the communications port that matches the one being used by the host
computer.
Selections: UNIDIRECTIONAL, BIDIRECTIONAL
Default Value: UNIDIRECTIONAL
To modify this parameter:
Press the up or down arrow to scroll through the selections.
PRI NT PAGE
(APL-I mode only)
Print Stored APL-I Page
Up to 20 pages can be stored and printed.
Selections: 0 through 19
Default Value: 0
To modify this parameter:
To increase the value, press the up arrow.
To decrease the value, press the down arrow.
PRI NT FORMAT
(APL-I mode only)
Print Stored APL-I Format
Up to 100 formats can be stored and printed.
Selections: 0 through 99
Default Value: 0
To modify this parameter:
To increase the value, press the up arrow.
To decrease the value, press the down arrow.
BAUD Set Baud
The baud setting of the printer must match the baud setting of the host
computer for accurate communications to take place. Select the value that
matches the one being used by the host computer.
Selections: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800,
38400, 57600, 115200
Default Value: 9600
To modify this parameter:
Press the up or down arrow to scroll through the selections.
Table 12 • Printer Parameters, Password Level 3 (Page 2 of 10)
Parameter Explanation
Loading...