Loading...
47
Operations
Password Protection of Parameters
10/27/05 S4M Maintenance Manual 13291L-001 Rev. A
Password Protection of Parameters
The printer has four levels of passwords. When you enter Setup mode on the control panel,
only those parameters that are not password-protected are displayed. To see more parameters,
you must enter an appropriate password at the ADVANCED SETUP prompt. After you enter a
password correctly, you do not have to enter it again until you leave and reenter Setup mode.
When you are prompted for a password, enter the password for the level displayed or for a
higher level. Entering a higher level password will unprotect the parameters for that level and
for all levels below it (for example, unprotecting level 4 parameters also unprotects levels 1, 2,
and 3).
The password levels and default passwords are shown in Table 8.
To enter a password when prompted, complete these steps:
1. When the printer displays ADVANCED SETUP X, press ENTER.
The printer displays PASSWORD and the number 0000.
2. Enter the four-digit password for the password level displayed or for a higher level.
The left and right arrows change the selected digit position.
The up and down arrows change the value of the selected digit.
3. After entering the password, press ENTER.
If you entered a valid password, additional parameters are displayed.
Table 8 • Password Levels and Defaults
Password
Level Features Controlled Default Password
4All features, including sensor adjustments
and other sensitive parameters
9999
3Installation and reconfiguration. The printer
web-page interface also uses this password.
1234
2Label configuration operations (media type,
label removal method, label length)
0000 (unprotected)
1Darkness, Tear-Off position, label top 0000 (unprotected)
Loading...
Terms of Use | Privacy Policy | DMCA Policy
2006-2020 Rsmanuals.com