Loading...
299
Preventive and Corrective Maintenance
10/100 Internal ZebraNet PrintServer, Wireless Print Server, Parallel Port, No Comm
10/27/05 S4M Maintenance Manual 13291L-001 Rev. A
Remove the Main Logic Board
1.
Connect yourself to an antistatic device.
2. See RRP No. 1 on page 122 and remove the electronics cover.
3. See Figure 162. Remove all cables from the main logic board.
Figure 162 • Remove the Main Logic Board Connections
Note • Retain all parts removed during disassembly, unless otherwise directed.
Caution • Observe proper electrostatic safety precautions when handling
static-sensitive components such as circuit boards and printheads.
Note • Take note of the location of all connectors on the main logic board.
1Printhead data (J3) 7Transmissive sensor (P9)
2Power-in (J8) 8Reflective sensor (P7)
3Front panel (J2) 9Take-label sensor (J19)
4Stepper motor (J9) 10 Communication expansion
port (J17)
5Booster board (J7) 11 USB (J14)
6Ribbon sensor, head Open
(P4)
12 Serial port (J10)
F6
L
F
1A
1
2
3
4
5
6
7
8
10
11
12
9
Loading...
Terms of Use | Privacy Policy | DMCA Policy