LED Indication
Several indicators messages are used to display the current projector status or alert the abnormal message.
Power LED
LED Display Projector status Procedure
Off AC Power is turned off
Flashing Green Projector is turning on. Wait till projector start displaying
Orange Projector is under cooling Wait until cooling finish ( ~ 120 sec)
On Red Standby mode
Green Projector is on
Status LED
LED Display Projector status Procedure
Off Normal status
Flashing
Red (Cycles of 1) Cover is opened. Check if the top cabinet is installed properly.
Red (Cycles of 4) Cooling fan error Contact with your nearest authorized dealer or service
center.
On Red System Error Contact with your nearest authorized dealer or service
center.
Light Source LED
LED Display Projector status Procedure
Off Light source is off
Flashing Green Projector is turning on.
Red (Cycles of 6) Light source lit fail Contact your nearest authorized dealer or service center.
On Red Light source is end-of-life Contact your nearest authorized dealer or service center.
Green Light source is on
Temp LED
LED Display Projector status Procedure
Off Normal status
Flashing Red Over temperature error Contact your nearest authorized dealer or service center.