Loading...
MV-5 - Kramer Protocol 3000
77
Description
Function #
Parameter
Value
Notes
Window input
HDCP
335
0
Source is not protected HDCP or
this input
is forced to be HDCP incompatible
STATUS (READ
ONLY)
1
Input HDCP is active, but the
window is removed
or blanked due to HDCP mode
settings
Input HDCP is active and this
window is
WND_HDCP[4]
for background
2
present on output image (HDCP
monitor only)
Target file for
image saving
Additional
parameter [x]
defines a
window that
contains an
image to save
336
0
1
2
3
4
No File
File A
File B
File C
File D
Source file for
image recalling
Additional
parameter [x]
defines a
window that
contains the
recalled image
If [x] = 4 then to
background
337
0
1
2
3
4
No File
File A
File B
File C
File D
Recalled Image
STATUS
READ ONLY
If [x] = 4 then
Status of
background
338
RCL_ACT[5]
0
1
2
3
4
No recalled File in this window
File A recalled and active
File B recalled and active
File C recalled and active
File D recalled and active
No input signal
handle
400
0
BLACK SCREEN
mode
1
BLUE SCREN
2
Remove window
3
Freeze last picture
LCD brightness
401
[-100:0]
LCD brightness while keyboard
activated
If LCD_BRGHT=0 - brightness =
100%
LCD brightness in sleep mode
(after 2 min
LCD brightness
in sleep
402
[-100:0]
keyboard is non-activated)