MV-5 - Configuring and Operating the MV-5 Locally
29
8. Press Menu to exit the sub-menu.
The display changes to show the Window Configuration sub-menu.
9. Press Menu again to exit the menu.
The display changes to show the default Window-Input configuration.
Note: Setting the Window border color green and blue values is performed in the
same manner.
7.1.6 Input Signal Status Sub-menu
The Input Status sub-menu displays the input states and is read-only.
Parameter
Description
Window 1 (or 2, 3 or 4) Input:
Signal:
Displays the input currently selected for each window and
the signal detected
DVI Background Input:
Signal:
Displays the signal currently detected on the DVI
Background input
7.1.7 System Parameters Sub-menu
The System Parameters sub-menu allows you to view the current firmware
version, serial number, serial port parameters, and to view and edit the Ethernet
port parameters.
Parameter
Description
Values
MV-5 HW Revision FW
Version
Hardware revision firmware number
and version
MV-5 Serial Number
Serial Port Baud Rate
Ethernet IP address
MV-5 device TCP/IP address
Ethernet Subnet Mask
MV-5 device network mask
Ethernet IP Gateway
MV-5 network gateway
DHCP Enable
Enables and disables automatic IP
addressing
Ethernet UDP Port Number
Sets the TCP UDP port number.
One item for three lowest significant
digits; second item for 2 highest
significant digits