Loading...
331 32nd Ave, PO Box 5128, Brookings, SD 57006
Phone: 877-605-1113 Fax: 605-697-4444
Website: www.daktronics.com
115
7. Field 3 contains information on the second team name. Click the up arrow or type “3” next to
Field. Under RTD Field, change Item # to 51 and Length to 25.
8. Field 4 contains information on the second team score. Click the up arrow or type “4” next to
Field. Under RTD Field, change Item # to 76 and Length to 2.
9. Field 5 contains information on the second team name. Click the up arrow or type “5” next to
Field. Under RTD Field, change Item # to 101 and Length to 25.
10. Field 6 contains information on the second team name. Click the up arrow or type “6” next to
Field. Under RTD Field, change Item # to 126 and Length to 2.
11. Field 7 contains information on the second team name. Click the up arrow or type “7” next to
Field. Under RTD Field, change Item # to 151 and Length to 25.
12. Field 8 contains information on the second team name. Click the up arrow or type “8” next to
Field. Under RTD Field, change Item # to 176 and Length to 2. To display more scores, continue this
process.
13. After inserting the number of fields needed, click OK to close the Frame Properties window.
14. Delete the first blank frame by clicking the First
Frame button. Click the Delete Frame button;
click Delete Current. Click Close.
15. Click the Preview button to preview the sequence.
After previewing, click Stop.
16. Save and Close the sequence.
Troubleshooting File RTD
1. To check that the item numbers are accurate, go to the Venus 7000 Shell and select Diagnostics. In
the Diagnostics window, click the RTD tab. Click the down arrow under Input and choose the
input that was configured. For this example, choose Input 10. In the lower window, all data
coming through from the file appears.
2. Verify the first blank frame is deleted.
3. Preview the frame at any time to check that the data comes through correctly.
4. Occasionally, some garbage data (information not contained in the .txt file) appears on a frame.
To prevent this, space through all 25 spaces on each line using the [space bar]. This alleviates
garbage data.
5. If the data comes through on the Diagnostics tab but not in the Preview window, check the text
color of the RTD fields, as the text color may have defaulted to black.
Loading...
Terms of Use | Privacy Policy | DMCA Policy
2006-2020 Rsmanuals.com