4211-82-G 08-01-14 7014132 314 SKSM 104 K
INSTALLATION AND OPERATING INSTRUCTIONS Page 5
WARNING
SECTION 7: OPERATION
The heater is intended for use with a SC-9, SC-60 or SC-CLUB Control
Panel only. Use with any other control voids the warranty and UL listing.
For health and re safety, never attempt to alter or bypass the timer or
thermostat. If the sauna is to be used without an automatic timer provided,
(Model SC-CLUB Control Panel) an attendant must be present at all times.
MODEL SC-9 CONTROL PANEL, UL Number 19-8-1517 ( 9 Hour Delay 1
Hour Operation Option ) This control is equipped with a 60 minute timer
with a 9 hour delay, an electronic thermostat, a light switch, and a pilot
lamp that indicates when the heater is on.
SETTING THE TEMPERATURE: The temperature can be adjusted by turning
the thermostat knob. To raise the temperature, turn the knob clockwise; to
lower the temperature, turn the knob counter-clockwise.
SETTING THE TIME: If you want the heater to begin heating immediately,
turn the dial clockwise past the rst marked section labeled "off to 1" (See
Diagram 4), then turn the dial back (counter-clockwise) until you feel it
"click", near the on position, into the one hour operating zone.
The heater has a "9 plus 1" timer, which means you can set the heater to
begin heating after a delay of up to 9 hours. If you set the timer dial in the
"1 to 9" zone, the heater will automatically turn on after the selected delay
time has elapsed.
Light Switch: Use the light switch to turn the sauna room light on and off.
MODEL SC-60 CONTROL PANEL, UL Number 19 - 8 - 1817 ( 60 minute
timer ) This control panel has a 60 minute timer, an electronic thermostat, a
light switch, and a pilot lamp that indicates when the heater is operable.
SETTING THE TEMPERATURE: The temperature can be adjusted by turning
the thermostat knob. To raise the temperature, turn the knob clockwise; to
lower the temperature, turn the knob counter-clockwise.
SETTING THE TIME: Use the timer to turn the heater on. To start the
heater, turn the timer knob clockwise to the desired time setting. Maximum
operating time is one hour.
Light Switch: Use the light switch to turn the sauna room light on and off.
Do not locate benches over
heater. Minimum clearance of
ceiling above heater 44".
Minimum clearance from
heater to wooden surfaces
(benches, side walls, heater
fence etc.) 2 inches. Mounting
brackets supplied. Provides
proper clearance from wall
behind heater.
Use only copper wire of the
size and type indicated in the
Heater Specication Chart and
the temperature rating
indicated on the heater
junction box.
All heaters and controls must
be grounded per NEC to
prevent electrical shock in
case of unit failure.
Electrical outlets or receptacle
must not be installed in a
sauna room.
A guardrail or fence is required
around the heater to prevent
burns from accidental contact.