Loading...
4209-51 06-08-09
page 14
SECTION 7: DISABLING OPTION DISPLAY
If an option (Chromatherapy Lighting, Fragrance Injector Pump, or EvenSteam Air Circulation Fan) is not in-
stalled, you have the ability to prevent the remote control display from showing these menu items. To disable the
option incons/menus from appearing on the display, set the jumpers over the option pins on the printed circuit board
inside the generator as shown below.
PLACE JUMPER
ON BOTH PINS
IF OPTION IS
NOT INSTALLED
PLACE JUMPER ON ONE PIN
FOR NORMAL OPERATION
PLACE JUMPER ON BOTH PINS
FOR USE WITH A TIMER
CONNECTED TO TB1
PLACE JUMPER
ON ONE PIN
IF OPTION
IS INSTALLED
PLACE ON BOTH PINS FOR
PLACE ON ONE PIN FOR
BATH TIME DISPLAY
60 MIN
24 HR C
F
llklk
1. Wait for the steam room to reach a comfort-
able temperature.
Remove clothing and jewelry.
Enter the steam room and close the door to
prevent steam from escaping.
Relax and enjoy the warm steam releasing
tense muscles and refreshing the entire body.
If your steam room has a shower, a pleasant
experience can be achieved by taking a warm
shower with the steam.
After a steam bath, a warm shower will give
you a feeling of relaxation and is conducive to a
good night’s rest. A cold shower will refresh you
and is a good way to start a busy day or prepare
you for an evening out.
SECTION 8: TAKING A STEAMBATH
SECTION 9: MAINTENANCE OF YOUR AK STEAM GENERATOR
The steam generator, steam head, fittings and
plumbing connections should be inspected regu-
larly for water leaks and damage. The AK steam
generator is equipped with a manual drain valve
for flushing sediments from the generator tank.
This procedure should be scheduled monthly or
more often depending on local water conditions
and steam bath usage, (if an optional auto drain
valve has been installed, this maintenance step
may be skipped.
The generator should be cool.
Press the control ON.
Open the manual drain valve.
The unit will drain without heating the water.
Allow the water to run for a full 10 minutes.
Push the control OFF. When the water stops
flowing out the drain, close the manual drain
valve.