3. Set Circuit Parameters: For this example, Circuit Module
3 will be used for Monitor Mode setup. Type ]P 3 and
press [Enter]. The Circuit Parameters Menu will appear.
a) Default Position = "A": Type 6, press [Enter], and
follow the instructions in the submenu to select path
"A" as the default path.
b) Enable Monitor Mode: Type 7, press [Enter], and
follow the instructions to enable the Monitor Mode.
c) Switch if Level = 0: Type 8, press [Enter], and follow
the instructions to select "0". This will trigger the
switch/notify routine when the signal drops.
d) Switch to Position B: Type 9, press [Enter], and
follow the instructions to select path "B".
e) Delay Period = 1 Minute: Type 10, press [Enter], and
follow the instructions to select 1 Minute.
f) Circuits to Switch = 3, 4, 5, 6: Type 12, press
[Enter], then select circuits 3, 4, 5, and 6.
g) Return = Yes: Type 11, press [Enter], and follow the
instructions to enable the Return feature.
h) Exit: Press [Esc] to exit the Circuit Parameters Menu.
5. Operation: When the switch is open, the input level will
remain at 1, and the circuits will remain in the default (A)
path. If the switch closes for more than 1 minute, the input
level will drop to 0, and the circuits will be automatically
switched to the "B" path.
a) Circuits 3, 4, 5, and 6 will automatically switch to "B".
b) If the switch returns to the open position, circuits 3, 4,
5, and 6 will return to the default "A" path.