b) Press [Esc] to exit the System Options Menu and return
to the AFS> prompt.
4. Set Circuit Parameters: For this example, Circuit Module
4 will be used for Monitor Mode setup. Type ]P 4 and
press [Enter]. The Circuit Parameters Menu will appear.
a) Default Position = "A": Type 6, press [Enter], and
follow the instructions in the submenu to select path
"A" as the default path.
b) Enable Monitor Mode: Type 7, press [Enter], and
follow the instructions to enable the Monitor Mode.
c) Switch if Level = 0: Type 8, press [Enter], and follow
the instructions to select "0". This will trigger the
switch/notify routine when the signal drops.
d) Switch to Position B: Type 9, press [Enter], and
follow the instructions to select path "B".
e) Delay Period = 1 Minute: Type 10, press [Enter], and
follow the instructions to select 1 Minute.
f) Circuits to Switch = 4, 5, 6, 7: Type 12, press
[Enter], then select circuits 4, 5, 6, and 7.
g) Send Notify Message = Yes: Type 14, press [Enter],
then enable the Notify Message.
h) Exit: Press [Esc] to exit the Circuit Parameters Menu.
5. Operation: When DTR signal is present (high), the
circuits will remain in the default (A) path. If DTR drops
for more than 1 minute, the input level will drop to 0 and
the switch/notify routine will begin.
a) Circuits 4, 5, 6, and 7 will automatically switch to "B".
b) The Notify Message will be sent to the Control PC.