5.2. Enabling the No-Data Alarm
1. Enter the Command Mode. Invoke Command ^B14 to define the Callback Parameters.
Note that Command ^B14's "ALARM#?" prompt is used to define the number that is
dialed when a No-Data Alarm is generated.
2. Type ^B15 [Enter], PollCat III will display a series of prompts as shown in Figure 5.1.
Key in the desired response to each prompt and then press [Enter].
a) ALARM?: Type Yto enable the No-Data Alarm, or Nto disable the alarm and press
[Enter].
b) PollCat III will display two prompts which are used to define the maximum time the
unit will wait before generating an alarm when no PBX data is received.
i. TIMER 1: Define the maximum length of time between calls during the
majority of the day (01 to 99 minutes).
ii. TIMER 2: Define the maximum length of time between calls during periods of
low PBX activity, e.g., lunch hour (01 to 99 minutes).
iii. If you make a format error while responding to the timer prompts, the prompt
will be redisplayed, allowing the time value to be re-keyed.
5-2
PollCat III - Pollable Call Accounting Terminal, User's Guide The No-Data Alarm
NO PBX ALARM
------------
ALARM: Y
TIMER 1: 30 MINUTES
TIMER 2: 90 MINUTES
ALARM SCHEDULE
--------------
WEEKDAY 1: 07:30-16:30
WEEKDAY 2: 11:30-13:00
WEEKEND 1:
WEEKEND 2:
HOLIDAYS
--------
01/01 07/04 09/06 11/25 12/24 12/26
COMPLETE
Figure 5.1: The No-Data Alarm Parameters Screen