c) PAGER ID #1? (Up to 15 characters) The number used when a Toll Fraud Alarm,
No-Data Alarm, or Pager Test is generated, and either Pager Notification feature is
enabled. In order to use Pager Notification, "PAGER ID #1" must be defined. If the
Alarm Clue definition does not specify a Pager I.D. number, Pager ID #1 will be used
by default.
d) PAGER ID #2? (Up to 15 characters) The second (optional) pager I.D. number used
when a Toll Fraud Alarm is generated and Pager Notification is enabled. If alarm
messages will only be sent to one pager (PAGER ID #1), this item is not needed.
e) PAGER ID #3? (Up to 15 characters) The third (optional) pager I.D. number used
when a Toll Fraud Alarm is generated and Pager Notification is enabled. If alarm
messages will only be sent to one pager (PAGER ID #1), this item is not needed.
f) MSG? (Up to 64 characters) The text that is sent when a Callback is initiated. Often
used to identify the installation site.
g) REDIALS? (Zero to 255, default = 4) The number of times PollCat III will redial the
Callback Number when there is no answer or no carrier is received. Approximately
10 seconds will elapse between redials.
h) RESTARTS? (Zero to 255, default = 3) (Binary Block Mode and Pager Alarm Only)
The number of times PollCat III will re-start the Callback routine if the defined
number of Redials is performed and there is no answer or the carrier is lost.
i) REXMITS? (Zero to 255, Default = 5) (Binary Block Mode only) The number of
times PollCat III will attempt to re-send a data block if there is a transmission error.
j) TIMEOUT? (One to 255 seconds, Default = 3 seconds) (Binary Block Mode only)
The maximum length of time PollCat III will wait if no response to a binary block is
received before a REXMIT.
Notes:
To skip a parameter without changing the current value, press [Enter] without
typing in a new value.
To clear a parameter and return to the default setting, press [Space] and then
[Enter].
To exit from the ^B14 routine and save currently defined parameters, press [Esc].
2. Type ^B16 [Enter] to display the Status Screen. Check to make certain that Callback
Parameters are correctly defined.
4-12
PollCat III - Pollable Call Accounting Terminal, User's Guide Program Set-Up