Cmd. Description / Options
^B87 Select Alarm Notification Method
^B87,0 No Alarm (Default)
^B87,1 Local PC
^B87,2 Remote PC
^B87,3 Pager (Alpha)
^B87,4 Report Mode
^B87,5 Pager (Numeric)
^B88 Test/Toggle ALM LED and Alarm Port
^B88,1 Alarm Off (Default)
^B88,2 Alarm On
^B89 Test Pager
^B90 Define Modem Port Communication Parameters
^B90,baud_rate,parity,data_bits,stop_bits
^B91 Define Computer Port Communication Parameters
^B91,baud_rate,parity,data_bits,stop_bits
^B92 Define PBX Port A Communication Parameters
^B92,baud_rate,parity,data_bits,stop_bits
^B93 Define PBX Port B Communication Parameters
^B93,baud_rate,parity,data_bits,stop_bits
^B94 Enter Monitor Mode
^B94,A Access PBX Port A
^B94,B Access PBX Port B
^B95 Display EPROM Version
^B99 Save Current Parameter Settings
^B99 All Parameters, Line by Line
^B99,* All Parameters, Condensed
^B99,0 "00" Series Parameters
^B99,1 ^B12 Callback Schedule
^B99,2 ^B14 Callback Parameters
^B99,3 ^B15 No-Data Alarm Parameters
^B99,4 "40" Series Command Parameters
^B99,5 "50" Series Command Parameters
^B99,6 "60" Series Command Parameters
^B99,7 "70" Series Command Parameters
^B99,8 "80" Series Command Parameters
^B99,9 "90" Series Command Parameters