PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
17. Execute Commands: The default Auto Execute command string.
This command string will be invoked when Auto Execute is enabled,
and a Callout or Console Action is generated. The command string
consists of a series of ^Bxx commands, which are listed in the
Command Help Screen, and Section 19.
Example: To send the Site ID Message and then send all alarm
records, the Auto Execute Command String would be defined as
"03/01,ALM". Note that the ^B is not included in the command
string, and that each command is separated by a slash (/).
18. Send Alarm Record: Enables and configures the "Send Alarm
Record" option for the Alphanumeric Page action. When enabled,
the VIP will include the record that triggered the alarm in the text
that is sent to your Alphanumeric pager. Please consult your pager
service when configuring the Maximum Message Length, Multi-Block
Message and Strip Control Codes options.
Note: The "Send Alarm Record" function applies to the Alarm
Filters only. This function is not available to the PBX Inactivity
Alarms or the 80% Full Alarm.
19. Email To: Determines the default recipient for emails that are
generated by the various alarms. This prompt allows you to select
either, both or none of the two email recipients that are defined via the
Send Email Configuration Menu, as described in Section 5.4.5.1.