Loading...
3.1.2.3. Force Broadcast (Sw8)
When the Force Broadcast feature is enabled, data sent to the Control Port will be distributed
to all four ports, without the need to first send a command to select the ports. In other words,
when this feature is enabled, all four ports will always be connected to the Control Port.
Note that when the Force Broadcast feature is enabled, ASCII port connection commands will
have no effect. The table below shows the setup switch configuration for the Force Broadcast
feature.
* = Factory Setting
U=Up
D= Down
Force Broadcast
Feature
Option Setup Switch
Sw8
Enable U
Disable * D
3.1.2.4. Force CTS and/or DCD High (Sw9 and Sw10)
The table below shows the setup switch configuration for these options.
* = Factory Setting
U=Up
D= Down
Option
Setup
Switch Function Enable Disable *
Sw9 Force CTS High D U
Sw10 Force DCD High D U
3.2. Connect Power Cable
Make certain that the CAS-41A power switch is in the OFF position and then connect the
power cable to the AC Power connector. Connect the other end of the power cable to an
appropriate grounded AC wall outlet.
3.3. Connect Data Cables
Note: Make certain that all data cables are compatible with the CAS-41A port
interface. Please refer to Appendix A for a description of the port interface.
1. Make certain that the CAS-41A power switch is set in the OFF position.
2. Connect data cables from the desired devices to Ports 1 through 4.
3. Connect the data cable from your Modem or PC to the CAS-41A's Control Port.
3-4
Installation
Loading...