Loading...
7-9
Status Screens
7.8. The Modem Port Status Screen
Communication Settings:
Com Settings: Baud Rate, Parity, Data Bits, Stop Bits, and
Handshake Mode for the Modem Port.
Reset String: The Modem Reset String.
Init. String: The Modem Initialization String.
Hang-Up String: The Modem Hang-Up String.
General Parameters:
Command Echo: The On/Off status of Command Echo feature at
this port.
Response Type: Upon login, this port will either display the Main
Menu immediately, or wait until [Enter] is pressed.
"Sure" Prompt: When enabled, a prompt is displayed before
destructive commands are completed.
CMD Port Timeout: The command mode timeout value for this port.
Audit Trail: When enabled, NetLink II will log command activity.
Action Parameters: The amount of time that will elapse between
alarm actions sent from this port.
Output Parameters:
Output Mode: The format used when data is released via this port.
Data on ^B01: When disabled, ^B02 is sent to begin data release.
Hold End Data: When enabled, ^B02 is sent to release the "End
Data" message.
PollCat NetLink II Version 2.0 02/16/2006 Thu 14:15 0% Full
MODEM PORT: Modem Installed
COMMUNICATION SETTINGS OUTPUT PARAMETERS
Com Settings: 57600,N,8,1,None Output Mode: ASCII Record
Reset String: ATZ Data on ^B01: On
Init String: ATE0M0Q1&C1&D2S0 Hold “End Data”: On
(Cont.): =1 Line # Tag: Off
Hang-Up String: (undefined) Send Compressed: Off
(Cont.): Auto Delete: Off
CALLOUT PARAMETERS
GENERAL PARAMETERS Dial Attempts: 2
Command Echo: On Sequence Attempts: 3 Att/10 Mins
Response Type: Inhibit Menu Immediate Callout: Off
“Sure” Prompt: On Immediate Phone #: (undefined)
CMD Port Timeout: 15 Mins (Cont.):
Audit Trail: Off Dialback Security: DB with Pswd
ACTION PARAMETERS
Action Delay: 300 Secs
Press <Enter> to return to menu ...
Figure 7.9: Modem Port Status Screen
Loading...