5-14
PollCat NetLink II - User’s Guide
Field Location:
11. Destination Number Location: This item is used to define the
beginning of the field that is normally used to store the destination
phone number. (1 to 216 Characters; Default = 16.)
12. Source Number Location: Defines the beginning of the field
that is normally used to store the source phone number. (1 to 216
Characters; Default = 34.)
13. Inbound Trunk Location: Defines the beginning of the field that
is normally used to store the inbound trunk number. (1 to 216
Characters; Default = 46)
14. Outbound Trunk Location: Defines the beginning of the field that
is normally used to store the outbound trunk location. (1 to 216
Characters; Default = 50.)
Field Length:
21. Destination Number Length: This item is used to define the length
of the field that is normally used to store the destination phone number.
(1 to 32 Characters; Default = 18.)
22. Source Number Length: Defines the length of the field that is
normally used to store the source phone number. (1 to 32 Characters;
Default = 12.)
23. Inbound Trunk Length: Defines the length of the field that
is normally used to store the inbound trunk number. (1 to 32
Characters; Default = 4.)
24. Outbound Trunk Length: Defines the length of the field that
is normally used to store the outbound trunk number. (1 to 32
Characters; Default = 4.)