Loading...
17-24
PollCat NetLink II - User’s Guide
^B83 Display Alarm Clue Summary
Displays a table which shows Clue Names, Threshold Counts, Match
Counts, and Alarm Status, sorted by input port and Alarm Filter matched.
To display Alarm Clue counter status, type ^B83 and press [Enter].
Command ^B83 uses the following format:
^B83[,port][,filter] [Enter]
Where:
,port Input Port: If this argument is omitted, ^B83 will display
the alarm clue summary for the Serial PBX Port. Offers the
following options:
,A Clue Summary for Serial PBX Port (Default)
,I Clue Summary for PBX IP Port
,filter Alarm Filter: Specifies the desired Alarm Filter. If this
argument is omitted, ^B83 will display the Clue Summary
for Alarm Filter 1. Offers the following options:
,1 Clue Summary for Alarm Filter 1 (Default)
,2 Clue Summary for Alarm Filter 2
Corresponding Menu Function: Status Displays, items 41, 42, 51 and 52.
^B84 Clear Alarm Condition
Clears the Alarm Condition and cancels Alarm Actions, without resetting
the Alarm Clue Counters or turning off the ALM LED.
Command Options:
^B84 Clear Alarm Condition
^B84,y Suppress "Sure?" Prompt, Clear Alarm Condition.
Corresponding Menu Function: System Functions, item 3.
^B86 Reset Alarm Clue Counters
Resets counters for specified Alarm Clue to zero. To clear an alarm
condition, please use command ^B84.
Command Options:
^B86,"clue" Reset Counter for clue only.
^B86,*,A1 Reset All Counters for Alarm Filter 1.
^B86,*,A2 Reset All Counters for Alarm Filter 2.
^B86,* Reset all counters for Alarm Filters 1 and 2.
Note: If both Alarm Filters include a clue with the same name,
command ^B86 must specify the desired alarm filter.
Corresponding Menu Function: System Functions, item 4