15-2
PollCat NetLink II - User’s Guide
15.1.1. Partitions and Files
When data is received from the PBX, NetLink II sorts each record into
one of six possible "files." Records are sorted according to Data Type
and Source Port. There are three Data Types; Standard Data (Non-Alarm
Records), Records that match Alarm Filter 1, and Records that match Alarm
Filter 2. There are two source ports; the Serial PBX Port and the
PBX IP Port.
As shown in Figure 15.1, each file contains a specific data type received
from a specific port. When a command port sets a partition, that port
is granted ownership of one or more of these files. The File List screen
(Status Displays, Item 2) can be used to determine which files are linked to
each command port.
Note that these files are always "open"; new data is continually added to
each file. When a partition is set, all records received up to that point will
be available for reading or erasure. However, new records received after
the partition is set will not be available until the partition is reset.
Note also that the "Store Alarm Data" option can be used to override
the default storage location for alarm records. Using this option, alarm
records for a selected port can be stored in the Alarm Files, in the Standard
File (Non-Alarm), or in both the Alarm File and Non-Alarm File. This
allows Alarm Records to be used for call accounting purposes only, alarm
tracking only, or for both. The "Store Alarm Data" option is located in the
configuration menus for the serial PBX Input Port and the PBX IP Port.
Figure 15.1: Data Partitions and Files
Loading...