14-3
Saving NetLink Parameters
2. Access command mode as described in Section 17.1.
a) If the password function is enabled, enter the valid Administrator
Level password. NetLink II must be operating in Administrator
Mode in order for the download command to function.
b) Note that this procedure can be performed from anywhere in the
NetLink II menu system.
3. Before invoking Command ^B99, make certain the command echo
is disabled at the NetLink II command port which will drive the
download. If the command echo is enabled when Command ^B99 is
invoked, the ^B99 command will be included in the file with the saved
parameters. This will cause problems when the file is uploaded to the
NetLink II unit,
a) The Command Echo is enabled/disabled using the Port
Configuration Menus as described in Section 5.4.
b) If desired, the command echo can also be temporarily suppressed
by entering the ^A character in place of the ^B character
(e.g. ^A99). Note that this method can also be applied to other
^Bxx commands to temporarily suppress the command echo.
4. Invoke command ^B99. From any NetLink II command menu, type
^B99 (or ^A99) and then press [Enter]. NetLink II parameters will
be sent to the polling device, where they will be saved to the ASCII
filename selected in Step 1.
a) Invoke the appropriate command to exit from your
communication program's Receive Parameters Mode when the
download is complete.
SYSTEM FUNCTIONS:
1. “Passthrough” Mode
2. “Monitor” Mode
3. Clear Alarm Condition
4. Clear Alarm Clue Counters
5. Download Parameters
6. Audit Trail Functions
7. Upload Firmware
8. Download SSH Server Key
Enter selection,
Press <ESC> to return to previous menu ...
Figure 14.1: System Functions Menu