Alarm Actions
12.2.2. Callout
If "Callout" is selected, NetLink II will call a remote modem when an alarm
is generated. After contacting the modem, NetLink II can then send an
Alarm Message and/or execute a user-defined command string. Typically,
the Alarm Message describes the type of event that has occurred, and the
Auto Execute Command string will usually report status or prompt the
NetLink II to download data.
Note: In order to use the Callout action, Modem Port parameters
must first be properly defined as described in Section 5.4.4.
When the Callout action is selected, the following items must be defined at
the configuration menu for the specified alarm:
Phone Number: Enter the number for your remote modem.
Message: (Optional) Enter a message to describe the type of alarm
event that occurred; for example "CHECK PBX".
Auto-Execute: (Optional) Enable the Auto-execute function and then
define the command string at the "Execute Commands" prompt. Auto
Execute command strings are discussed further in Section 12.3.
12.2.3. Alphanumeric Page
When this Alarm Action is selected, NetLink II will dial up to three
alphanumeric pagers when an alarm is generated. After contacting each
pager, NetLink II can then send an Alarm Message that describes the nature
of the alarm.
Note: In order to use the Alphanumeric Page action, Modem Port
communications parameters must be properly defined as described
in Section 5.4.4.
When Alphanumeric Page is selected, the following items must be defined
at the configuration menu for the specified alarm:
Phone Number: Enter the number for your pager service.
Pager ID Numbers: Enter up to three Pager ID numbers. When
an alarm is generated, NetLink II will contact all defined Pager ID
numbers, starting with Pager ID #1.
Message: (Optional) Enter a message to describe the type of alarm
event that occurred; for example "80% FULL".