Loading...
8-20
Alarm Configuration
• NotifyUponClear: When this item is enabled, the RPC will send additional
notification when the situation that caused the alarm has been corrected. For
example, when Notify Upon Clear is enabled, the RPC will send initial notification
when it detects that the dialtone for the external modem has been lost, and then
send a second notification when it determines that the dialtone has been restored.
(Default=On)
• EmailMessage:Enables/Disablesemailnotificationforthisalarm.(Default=On)
• Address1,2,and3: These parameters are used to select which of the three email
addresses defined via the "Email Messages" menu (see Section 6.8.10) will receive
the email alarm notification messages generated by this alarm. The Address
parameters can be used to select one, or any combination of the addresses defined
viatheEmailMessagesmenu.(Default=AllOn)
Note:IfEmailaddresseshavebeenpreviouslyspecified,thenthetextunder
the parameters will list the current, user defined email addresses.
• Subject: This parameter is used to define the text that will appear in the "Subject"
fieldforallemailnotificationmessagesgeneratedbythisalarm.(Default="Alarm:
No Dial Tone")