8.2.2. Configuration
The Direct Connect Function is configured on a per port basis
using the RS232 Port Configuration Menus (/P nn), item 15,
"Direct Connect". The following options are available:
1. Direct Connect OFF: Direct Connect disabled at this
RS232 Port. (Default)
2. Direct Connect ON - NO PASSWORD: The Direct
Connect feature is enabled at this port, but no password is
required in order to connect to the port.
a) When the Telnet connection is established, the user is
immediately connected directly to the specified port,
and the client is notified at the TCP level.
b) This option is intended for situations where security is
provided by the attached device.
3. Direct Connect ON - PASSWORD: The Direct Connect
feature is enabled at this port, but the user must enter a
password before a Direct Connection is established with
this port.
a) Upon login, the CMS will send a message which lists
the Site ID Message, the number and name of this port,
and the TCP Port number that was entered in order to
initiate the connection.
b) The CMS will prompt the user to enter a password. If a
valid User password or Supervisor password is entered,
the CMS will then return a message that confirms the
connection and again lists the name and number of
this port.
c) If a valid User password or Supervisor password is not
entered in 30 seconds or three attempts, the port will
then timeout and disconnect.
8-3
Telnet Capabilities
Loading...