Loading...
To select common parameters for all or several CMS RS-232
ports, proceed as follows:
1. Access the CMS command mode. If the password prompt
is displayed, key in your Supervisor Level Password.
2. At the CMS command prompt, invoke the /CP command,
the menu shown in Figure 5.5 will be displayed.
a) All Ports: To copy parameters to all CMS ports,
type /CP [Enter].
b) Range of Ports: To copy parameters to a range of
CMS ports, type /CP m-n [Enter]. Where mand n
are CMS port numbers that specify the desired range.
For example, to copy parameters to ports 3 through 7,
type /CP 3-7 and press [Enter].
c) Several Ports: To copy parameters to several CMS
ports, type /CP m,n,x [Enter]. Where m,nand x
are the numbers for the desired ports. For example to
copy parameters to ports 3, 5, and 7, type
/CP 3,5,7 [Enter].
d) Combination: To invoke the /CP command in a
manner where a range of CMS ports is specified, along
with several other ports outside the range, type /CP
m,n,x-z [Enter]. Where m,n,x, and zare CMS
port numbers. For example to copy parameters to CMS
ports 3 and 5 plus CMS ports 7 through 9, type
/CP 3,5,7-9 [Enter].
3. Selecting Parameters: To select parameters to be copied,
key in the number for the desired parameter, press [Enter],
and then follow the instructions in the submenu. Note that
it is not necessary to define all port parameters; for
example, the /CP command could be used to select only the
Baud Rate for all specified ports.
Note: The /CP command will only copy the
parameters currently displayed by the Copy Port
Parameters menu. Although the Port Password is not
displayed, the selected password will be copied if the
field for this item reads “defined”.
5-22
CMS-16 / CMS-8 User's Guide