4.2.1. Default Baud Rate (Sw1, Sw2, Sw3)
Option Switches one through three select the default baud rate
for all CMS RS232 Ports. The default baud rate must match the
rate your control device will use when communicating with the
CMS. If the control device will communicate via modem, select
a default baud rate that is compatible with the modem.
SW
Default Baud Rate
123
DDD
9600*
UDD
300
DUD
1200
UUD
2400
DDU
19.2K
UDU
38.4K
DUU
57.6K
UUU
115.2K
* = Factory Setting
4.2.2. Default Handshake (Sw4, Sw5)
The default handshake format must match the format your
control device will use when communicating with the CMS.
Option Switches 4 and 5 can select RTS/CTS (hardware),
XON/XOFF, Both or None.
Switch Default
Handshake
45
DD
RTS/CTS *
UD
XON/XOFF
DU
Both
UU
None
* = Factory Setting