Loading...
TERMINATING FOUR-PAIR TWISTED CABLE
The SoloMaster Keypad Modules, the Expander, and the ZR-4630’s System Expansion connections require a
four-pair twisted cable with a one-to-one wiring configuration. To maintain consistency throughout all Intellipad
Ci installations, we recommend the color-coding pattern described in Figure 31. However, you may follow the
color-coding pattern of your choice, as long as it is used consistently throughout the system.
45
CONNECTIONS
1234
Pair 2
Pair 1
T568A
Pair 3 Pair 4
5678
1=Green/White
2=Green
3=Orange/White
4=Blue
5=Blue/White
6=Orange
7=Brown/White
8=Brown
Figure 31
Solo
Master
Keypad Module
Numeric
Accessory
Keypad Module
RJ-45 Connector for
connection to Master
Keypad Module
RJ-45 Connector
for connection to
Numeric Accessory
Keypad Module
RJ-45 Connector
for connection to
IR Sensors
RJ-45 Connector for
connection to
the ZR-4630
Included
Jumper Cable
IR SENSOR
INPUT
OUTPUT
SYSTEM
ACCESSORY
KEYPADS
Figure 32
Figure 33
CONNECTING
NUMERICKEYPADS
Each SoloMaster Keypad Module
can be mated with one optional
NumericAccessory Keypad Module
using an included jumper cable (see
Figure 33).
CONNECTING THE SOLOMASTER KEYPADS TO THE
HOME RUN OF FOUR-PAIR TWISTED CABLE
The home run of four-pair twisted cable is terminated with a male
RJ-45 connector and plugged into the rear panel jacklabeled SYSTEM
on the SoloMaster Keypad Module (see Figure 32).
Loading...