Loading...
4.2.1. Default Baud Rate (Sw1, Sw2, Sw3)
Option Switches one through three select the default baud rate
for all CMS RS232 Ports. The default baud rate must match the
rate your control device will use when communicating with the
CMS. If the control device will communicate via modem, select
a default baud rate that is compatible with the modem.
SW
Default Baud Rate
123
111
9600*
011
300
101
1200
001
2400
110
19.2K
010
38.4K
100
57.6K
000
115.2K
0 (Off) çè 1(On)
* = Factory Setting
4.2.2. Default Handshake (Sw4, Sw5)
The default handshake format must match the format your
control device will use when communicating with the CMS.
Option Switches 4 and 5 can select RTS/CTS (hardware),
XON/XOFF, Both or None.
Switch
Default Handshake
45
11
RTS/CTS *
01
XON/XOFF
10
Both
00
None
0 (Off) çè 1(On)
* = Factory Setting