11 SETUP/MAINTENANCE
Part No 1143151 99 Invacare 3G Storm Series®
Installing
1. Place the wheelchair in a well ventilated area where work can be performed without risking damage to carpeting or floor covering.
2. Verify the joystick On/Off switch is in the Off position.
3. Secure the battery box carrying strap to the lid of the two connector battery box.
4. Place two connector battery box onto the battery sub-frame assembly with guide pins facing the inside of the wheelchair.
5. Slide the two connector battery box along the sub-frame until its guide pins are engaged in the sub-frame connector.
6. Secure the battery box carrying strap to the lid of the one connector battery box.
7. Place one connector battery box onto battery sub-frame.
8. Slide one connector battery box along the sub-frame until its guide pins are engaged in the connector of the two connector battery box.
9. Pull the battery box retainer down over the end of the one connector battery box until it is securely clipped (locked) into place.
Visually inspect to ensure the connection is properly made. Connectors MUST be fully engaged.
Make certain that the battery box carrying strap is positioned on top of the battery box and will not interfere with the one
battery box guide pins when engaging the connector on the one battery box lid.
Visually inspect to ensure the connection is properly made. Connectors MUST be fully engaged.
CAUTION
The battery retainer assembly MUST be locked securely to hold the battery boxes firmly in place or battery box
connectors may be damaged causing erratic wheelchair operation.