Loading...
27
Set up and operation for DC PULSE TIG Welding
1. Select DC Pulse by pushing
selector key to cycle through to
illuminate DC Pulse icon.
2. Select Peak Current by pushing the selector button to
cycle through to illuminate the Peak Current Icon
3. Turn the Adjustment Knob to set the
Peak Current at 100A
(Range is 10-200 Amps)
4. Select the Base Current by pushing the selector key to
cycle through to illuminate the Base Current Icon
5. Turn the Adjustment Knob to set the Base
Current at 30A (Range is 10-200 Amps)
100A
30A
Peak
Amp
Base
Amp
7. Turn the Adjustment Knob to set the
Pulse Width at 60%. (Range is 10 - 90%).
6. Select the Pulse width ( % on time of the Peak Amp) by
pushing the selector key to cycle through to illuminate the %
Pulse Icon
100A
30A
Peak
Amp
Base
Amp
100A
60%
30A
40%
Peak Amp
On Time
Pulse Width
The Razorweld 315 machine has digital pulse frequency control. All the parameters for DC Pulse TIG
welding - Peak Amp, Base Amp, Pulse Frequency and Pulse Width are easy to set via the digital control
panel.
EXAMPLE OF PULSE DC TIG WELDING - SETUP PARAMETERS:
Material = Stainless Steel x 2.0mm / Tungsten Electrode = 1.6mm 2% Thoriated / Gas = Argon
The following steps are a guide as a starting point for you to set the machine up in Pulse mode to give an
example of welding in Pulse mode function. You can experiment by changing any of the variables to see
what effect it has over the welding and what the end result can be, but it is suggested to change only one
variable at a time and then check the welding to see what the result is, in this way you acquire a better
understanding of how each variable affects the welding current.
AC
AC
DC
AC PULSE
DC PULSE
DC
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
9. Turn the Adjustment Knob to set the
Pulse Hz to 2 Hz (Range is 0.5 - 200Hz)
8. Select the Pulse Frequency by pushing the selector key to
cycle through to illuminate the Pulse Hz Icon
Peak
Amp
Base
Amp
100A
60%
30A
40%
100A
60%
30A
40%
Time = 1 Second (Hz)
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz