Loading...
16
Front Panel Operation - LED Display Functions - Alarms
ADJUSTMENT
Turn the Encoder Knob
to adjust parameters
settings
7. LED Display Functions - Alarms : Provides display of parameters and alarm codes.
Parameter Settings: The display will
illuminate and display the welding current
during welding.
ALARM
Parameter Display - Provides display of parameter settings.
ALARM
Software version will display for
2 seconds and then revert to the
preset current of last used weld-
ing current setting.
Software Version Display: The soft-
ware version number will be show on the
display when the machine is powered up.
ALARM
Software Version Display - Provides display of the Version Software
ALARM
Other parameter settings will be
displayed as selected, such as
preset current time, pulse ratio, pulse
frequency etc.
Alarm E-1: Indicates over current
situation. Re-start the machine and
welding can continue.
Alarm E-2: Indicates that mains
voltage supply is overly low or the
secondary inverter drive fails. In

Supply the correct mains voltage.
For the inverter fail contact ask a
technician for checking.
Alarm E-0: Indicates over current
situation. Re-start the machine and
welding can continue.
ALARM
Alarm LEDs - Provides display of alarm condition and error code.
In normal condition, all alarm LEDs are off. In case of any error, the corresponding LED will illuminate
and the digital meter will display the corresponding error code
ALARM ALARM
Razorweld
Loading...
Terms of Use | Privacy Policy | DMCA Policy