Front Panel Operation - Weld Program Sequence Control
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
ADJUSTMENT
Post Gas Timer - 
Turn the Encoder to set
the Pre-Gas Time
(Range is 0-10 Sec)
Pre Gas Time: Select by pushing selector key to cycle through to
illuminate the Post Gas Timer icon.
The value selected shows on the
digital display. It is the length of


AC Balance AC Hz % Pulse Pulse Hz
AC Balance AC Hz % Pulse Pulse Hz
ADJUSTMENT
ADJUSTMENT
Pulse Frequency: Select by pushing selector key
to cycle through to illuminate the Pulse Hz icon.
Pulse Duty: Select by pushing selector key to cycle
through to illuminate the % Pulse icon.
Turn the Encoder Knob to
set the Pulse Frequency
DC Range 0.5~200Hz
AC Range 0.5~5.0Hz
Turn the Encoder Knob to
set the Pulse Width
(Range is 10 - 90%).
The value selected is shown in the
digital display. The value selected
is the amount of pulses per second
(Hz)
The value selected is shown in the
digital display. The value selected
is the % of ON time of the Peak
Current during each pulse cycle.
5. Pulse Mode Parameter Selection: Provides setting of the parameters for Pulse Frequency and Pulse Duty
in AC Pulse TIG and DC Pulse TIG Modes.
AC Wave Frequency Selection: Provides setting of the AC Wave Frequency (Hz) in AC TIG Mode
AC Wave Balance Selection: Provides setting of AC Wave + / - Balance in AC TIG Mode
Pulse Frequency - Provides setting of the amount of pulses per second of the Peak Current.
Pulse Duty - Provides setting of the % of time the peak current stays on within each pulse cycle.
AC Balance AC Hz % Pulse Pulse Hz
ADJUSTMENT
AC Hz: Select by pushing selector pad to cycle
through to illuminate the AC Hz icon.
Turn the Encoder Knob to
set the Pulse Width
(Range is 20-70 Hz).
The value selected is shown in the
digital display. The value selected
is how many times per second the
AC wave completes a full cycle.
AC Hz - Provides setting of the frequency that the direction of the AC wave (+ to -) completes a full cycle