Front Panel Operation - Weld Program Sequence Control
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
Parameter selection: Select by pushing selector pad to
cycle through to illuminate the icon of the parameter
required. Each push of the selector pad will move the icon
illumination in a clockwise cycle.
Indicates Action
Selector Key
4. Weld Program - Provides selection weld program parameters
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
ADJUSTMENT
Pre Gas Timer - 
Turn the Encoder to set
the Pre-Gas Time
(Range is 0-15 Sec)
Pre Gas Time: Select by pushing selector key to cycle through to
illuminate the Pre Gas Timer icon.
The value selected shows on the
digital display. It is the length of time

Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
ADJUSTMENT
Start Current - Provides selection for the amount of amps required at the start of the weld.
Turn the Encoder to set
the Start Current value
DC Range 10~320
AC Range 20~250
Pre Gas Time: Select by pushing selector key to cycle through to
illuminate the Start Amp icon.
The value selected shows on the
digital display. It is the amount of
amps the machine will deliver at the
start of the welding sequence.
Finish
Current
Start
Current
Peak
Current
Base
Current
AC Balance AC Hz % Pulse Pulse Hz
ADJUSTMENT
Up Slope Time - Sets the transition time from Start Amperage to Welding Amperage
Turn the Encoder to set
the Pre-Gas Time
(Range is 0-60 Sec)
Up Slope Time: Select by pushing selector key to cycle through
to illuminate the Up Slope icon.
The value selected shows on the
digital display. It is the amount of
time the welding current takes to
climb from start amperage to weld-
ing amperage.